Pathyaപഥ്യം
← New record

IndiPGx-Pop p108

Lab reportcohort · india-sim

10/30/2026, 1:57:35 PM · PharmCAT 3.4.0 · Research record, not medical advice

2
Genes standardised
2
Calls quoted
0
Coverage gaps
0
Identifiers removed
35.9s
Upload to record
  1. Muse Sparkread 2 gene calls25.4s
  2. PharmCATstandardised 2 genes10.5s
  3. Rules0 coverage gaps

CallsMuse Spark each call quoted from the source, then standardised by PharmCAT

Synthetic Genomics Lab (Kochi) · 17 Oct 2026 · open original photo

Uploaded lab report photo
GeneAs printedStandardisedPhenotype term
DPYD“No tested variant detected - Normal metabolizer (activity score 2)”Reference/ReferenceNormal Metabolizer · activity 2.0
UGT1A1“*28/*1 (TA7/TA6) - Intermediate metabolizer”*28/*1Intermediate Metabolizer

Method as printed: Method: targeted genotyping by real-time PCR. Only the listed variants are assayed; variants outside this panel cannot be excluded.

Coveragedeterministic rules · which India-relevant variants this panel named

DPYDHapB3named on the report

Most common Indian decreased-function DPYD variant (~3.3%, PMID 40810747)

DPYDc.85T>C (*9A)named on the report

~25% in Indians; toxicity signal in South Indian cohorts (PMC11300675)

DPYD*2Anamed on the report

European tier-1 variant; rare in Indians (PMID 40810747)

DPYD*13named on the report

Tier-1 no-function variant (PMID 39032821)

DPYDc.2846A>Tnamed on the report

Tier-1 variant; near-absent in Indians (PMID 40810747)

UGT1A1*28named on the report

TA-repeat allele, common in South Asians

UGT1A1*6named on the report

East Asian allele; reported at low frequency in India

A variant the panel did not name is left out of cohort statistics for that variant, rather than counted as absent. Reader notes: Only the listed variants are assayed; variants outside this panel cannot be excluded. DPYD: No tested variant detected - untested variants cannot be excluded. Synthetic document generated for software benchmarking. Not a real patient or laboratory.

Exportde-identified · the same record in three formats

Curator review

A curator checks each call against the source document before the record counts in a cohort, and Muse Spark web search finds published Indian frequency data for each variant. Both are written to the audit log. Reviewing is the one action that needs a curator code, because it is a claim that a person checked the page.

Sign in as a curator
Research tool, not medical advice. Pathya reads and standardises pharmacogenomic results; it makes no dose, drug or test recommendation. Audit log: data/cases/78537b5b4c1b/audit.log.